logo
Send Message
LINK-PP INT'L TECHNOLOGY CO., LIMITED
Products
News
Home > News >
Company News About SFP Cage Selection Guide: Single, Ganged, Stacked, and Belly-to-Belly Layouts
Events
Contacts
Contacts: LINK-PP Global
Fax: 86-752-3161926
Contact Now
Mail Us

SFP Cage Selection Guide: Single, Ganged, Stacked, and Belly-to-Belly Layouts

2026-11-19
Latest company news about SFP Cage Selection Guide: Single, Ganged, Stacked, and Belly-to-Belly Layouts


Choose a 1×1 SFP cage when you need to position ports independently, a 1×N ganged cage for one horizontal row of adjacent ports, or a 2×N stacked assembly for two rows on one side of the PCB. Consider a belly-to-belly layout when the board can accommodate separate cages on both sides. Before releasing the PCB and front-panel drawings, check the exact cage and host connector part numbers for footprint, pin clearance, bezel fit, EMI shielding, and module cooling.

Two SFP cage assemblies that accept the same pluggable transceiver can still require different PCB hole patterns, board thicknesses, bezel cutouts, or thermal hardware. Treating port topology, electrical speed family, and supplier-specific drawings as separate checks prevents layout rework during prototype bring-up.

Compare the Four SFP Cage Layouts

Labels such as 1×1, 1×N, 2×N, and belly-to-belly describe physical port arrangement and PCB mounting strategy—not data-rate capability. In particular, 2×N stacked and belly-to-belly are not synonyms: a stacked cage places two rows inside one assembly on one PCB face, whereas belly-to-belly mounts separate cages on opposite sides of the same PCB.

Layout Port Arrangement When to Consider It What to Check First
1×1 Single-Port Cage One independently placed port Low port count, mixed front panels (e.g., RJ45 + SFP), or designs needing flexible port spacing PCB footprint, host connector datum, thermal spacing, and release-latch clearance
1×N Ganged Cage
(e.g., 1×2, 1×4, 1×6)
One horizontal row in a shared frame Adjacent ports require shared front-panel alignment and compact horizontal width Overall width, port center spacing, bezel cutout, supplier-specific footprint, and airflow across populated ports
2×N Stacked Assembly
(e.g., 2×2, 2×4, 2×8)
Two vertical rows in one assembly on one PCB face Front-panel height allows two rows within limited panel width Assembly height, connector integration & routing, latch access, tooling, and module case temperatures on both rows
Belly-to-Belly Layout Separate cages mounted on opposite PCB faces Both PCB surfaces and top/bottom chassis clearances are available for ports Finished PCB thickness, opposing tail clearance, shared EMI hole rules, dual-side airflow, and assembly access

Port count and chassis geometry quickly narrow down the candidates. If four ports fit horizontally across the available panel width, a 1×4 ganged cage keeps them in one row; if eight ports must occupy roughly the same width, a 2×4 stacked assembly or a belly-to-belly 1×4 arrangement becomes a candidate. Check the exact drawings for bezel openings, usable chassis height, PCB clearance on both faces, and populated module case temperatures before committing to a layout.

1x1 vs 1xN ganged vs 2xN stacked vs belly-to-belly SFP cage PCB architecture comparison

Figure 1: Topological overview of 1×1 single, 1×N ganged, 2×N stacked, and belly-to-belly SFP cage layouts (the staggered belly-to-belly pin pattern shown is illustrative; always follow the supplier’s approved double-sided drawing).


1. Check the Module, Host Connector, and Cage as a System

The metal SFP cage guides and retains the transceiver, forms part of the chassis grounding and EMI shielding interface, and in some designs accommodates a heatsink. The electrical host connector mates with the transceiver’s card-edge contacts and carries high-speed signals into the PCB channel: Transceiver → Host Connector → PCB Channel → SerDes.

Before creating the schematic symbol and BOM, confirm the exact procurement structure of your chosen part number:

  • Discrete Cage + Separate 20-Position Host Receptacle: Common in 1×1 and many 1×N ganged designs. The SMT host receptacle is typically soldered to the PCB before the press-fit cage is seated over it—always confirm the assembly sequence in the supplier’s application specification.
  • Integrated Cage-and-Connector Assembly: Common in 2×N stacked designs, and also offered in selected 1×4 and 1×6 ganged press-fit assemblies. Verify whether the orderable part number is a cage only, a host connector, or an integrated assembly, as well as what seating tooling and rework procedures apply.
Two-piece SFP+ cage over a 20-pin SMT host connector and cross-section of a press-fit compliant pin in a PCB plated through-hole

Figure 2: Two-piece SFP+ cage positioned over a 20-pin SMT host connector (left) and schematic cross-section of a compliant press-fit pin seated in a PCB plated through-hole (right).


2. Separate Module Speed Families from Mechanical Cage Architecture

Do not infer a cage’s supported data rate from its port matrix, and do not assume that physical module insertion confirms electrical or EMC compatibility. Keep three definitions separate during design reviews:

  • Protocol Rate vs. Component Rating: Ethernet or Fibre Channel standards define protocol line rates (such as 10GbE), whereas connector/cage datasheets list maximum tested or rated data rates for specific part numbers. For example, TE Connectivity lists its 2180739-1 SFP+ cage at up to 16 Gb/s—that is a component capability rating, not a statement that 10G Ethernet runs at 16 Gbps.
  • zSFP+, SFP28, and SFP56 Naming: zSFP+ is a supplier-specific product family name (such as TE’s zSFP+ interconnect line covering both SFP28 and SFP56 applications with part-number-dependent dimensions and ratings), not a universal synonym for SFP28. Confirm the exact module, connector, and cage combination against the supplier’s drawing.
  • Upgrading Across Generations (SFP → SFP+ → SFP28 / SFP56): Faster signal edge rates and broader system frequency spectra increase demands on shielding continuity and channel integrity. Verify module mechanical latch engagement, host connector and PCB channel performance, module power limits, and full-chassis EMC testing rather than relying on mechanical plug-in fit alone.
Design Verification Question Starting SNIA / SFF Reference & Scope
SFP+ module & cage mechanical envelope SFF-8432 covers SFP+ module and cage mechanical requirements (including ganged and stacked concepts); it is a mechanical standard, not a system EMC guarantee.
Ganged SFP+ footprints & bezel openings SFF-8433 covers reference ganged cage footprints and bezel openings; always release the PCB using the exact supplier part drawing.
Card-edge host connector SFF-8071 covers the SFP+ 1× 0.8 mm card-edge connector (0.8 mm refers to connector contact pitch, not cage-to-cage port pitch).
Electrical & management interfaces SFF-8418 (SFP+ 10 Gb/s electrical), SFF-8419 (low-speed electrical and power), and SFF-8402 (physical, low-speed electrical, and management for covered families including SFP28 and SFP56, paired with applicable IEEE or Fibre Channel specs).

3. Review PCB Footprint, Hole Tolerances, and Board Thickness

There is no single universal PCB footprint or minimum board thickness for all press-fit SFP cages. Requirements depend on the exact part number, suffix, tail length, and mounting style.

Drawing Example — TE 2007263-1 vs. Other 1×2 Cages: Customer drawing TE C-2007263 specifies 14.25 mm center-to-center port spacing and a minimum PCB thickness of 1.50 mm for single-sided mounting or 2.25 mm for double-sided mounting, referencing TE 114-13120 for applicable hole designations. By contrast, TE’s product page for 2180739-1 (Active, 1×2, EMI springs) lists 2.25 mm as the recommended PCB thickness, while historical data for 2180900-1 (Obsolete, 1×2, elastomeric gasket) lists 1.50 mm. Never apply one 1×2 cage’s board thickness across an entire category.

Hole Designation (TE 114-13120 Rev G, Fig. 2) Recommended Drill Size Finished Hole After Plating (Ref.)
Hole A 1.15 ± 0.02 mm 1.05 mm Ref.
Hole B 1.05 ± 0.02 mm 0.95 mm Ref.
Hole C 0.95 ± 0.02 mm 0.85 mm Ref.

Scope note: The hole values above apply specifically to products governed by TE 114-13120, where the exact customer drawing designates which hole class (A, B, or C) is required at each coordinate.

Key PCB & Assembly Checks Before Gerber Release

  • Verify Surface Finish Against the Product Spec: Follow the exact cage application specification for PCB surface finish and hole-wall plating. For instance, TE 114-13120 Rev G lists approved finishes including SnPb HASL under defined conditions while noting Immersion Silver exclusions on certain 1×1 single-piece cages—avoid applying blanket finish rules across unrelated cages.
  • Check Stencil Masking & Ground Pad Design: Confirm whether compliant-pin PTHs must be masked out of the SMT solder paste stencil, and follow the supplier’s chassis-grounding layout rules (evaluating direct copper connection vs. thermal relief requirements against EMC/ESD targets).
  • Size Tooling & Seating Height per Specification: TE 114-13120 calculates estimated cage seating force for tooling sizing at number of compliant pins × 44.5 N per compliant pin, and checks an installed standoff gap of 0.10 mm max in applicable configurations (TE 114-13120 Rev G, Fig. 11 excludes light-pipe assemblies from that check). Use dedicated seating and extraction tooling for assembly and rework.
  • Use Approved Double-Sided Layouts for Belly-to-Belly: Never create a belly-to-belly layout simply by mirroring a single-sided footprint, as opposing compliant pins may interfere inside the holes. Use the supplier-approved back-to-back footprint and verify finished PCB thickness (e.g., 2.25–3.00 mm in specific TE cage families), tail length, and shared EMI suppression hole rules.

4. Bezel Cutout Fit and EMI Shielding Interfaces

Two 1×2 cages with similar port counts can require different front-panel geometry depending on their bezel EMI interface:

  • EMI Spring Fingers: Stamped metal fingers around the front perimeter that require a clean, conductive bezel surface at the specified contact zones and sufficient clearance for the module latch.
  • Conductive Elastomeric Gaskets: A compliant conductive collar around the cage face that relies on the contact geometry and compression specified by the supplier drawing.

Part-Level Contrast: TE 2180739-1 (Active) is a 1×2 press-fit SFP+ cage with EMI spring fingers and a heatsink opening, whereas TE 2180900-1 (Obsolete) is a 1×2 configuration with an elastomeric gasket and a heatsink slot. Always size panel cutouts (such as the 15.25 mm nominal width shown for a specific single-port PCI example in TE 114-13120) directly from the exact part drawing, check panel coatings and tolerance stack-ups, and verify emissions in full-chassis EMC testing.

SFP cage EMI spring fingers vs elastomeric conductive gasket contacting server front bezel cutout

Figure 3: Front bezel EMI sealing interfaces — metallic EMI spring fingers (left) vs. conductive elastomeric EMI gasket collar (right).


5. Cooling and LED Light Pipe Integration

Evaluate Thermal Margin Under Actual System Conditions

Do not approve a cage architecture using generic watt-per-port thresholds. Base thermal decisions on the maximum power and case-temperature limit of the actual transceivers you plan to support. As documented reference points in Cisco’s 10GBASE SFP+ datasheet (Tables 1 & 8), the SFP-10G-SR optical module is rated at 1 W (with other optical variants up to 2 W), whereas the SFP-10G-T-X copper module is rated at 2.5 W maximum at 10 Gb/s over up to 30 m on specified cabling.

When thermal margin requires an external heatsink, verify the cage’s heatsink opening, the riding heatsink contact interface, and the separate retention clip clearance, and select candidate fin orientations matched to chassis airflow:

  • Longitudinal Fins: Candidate design for front-to-back chassis airflow channels.
  • Pin-Fin Heatsinks: Candidate design for multi-directional or oblique fan airflow.
  • Transverse Fins: Candidate design for side-to-side cross-flow cooling paths.

Validate module case temperatures with all ports populated at maximum design ambient temperature, expected fan speed, and representative system backpressure—especially in 2×N stacked banks where both upper and lower rows must reject heat simultaneously.

Freeze Light-Pipe Coordinates Early

LED light pipes establish a fixed mechanical chain from PCB LEDs to the front bezel. Before freezing the layout, verify the indicator count (for example, 2 LEDs per port = 4 optical light-pipe channels on a 1×2 cage such as TE 2007262-1), LED pickup coordinates, front-panel hole positions, assembly order, and clearance around any riding heatsink or retention clip.

SFP+ cage with heatsink opening riding heatsink retention clip and rigid polycarbonate optical light pipes

Figure 4: Top heatsink opening with a riding finned heatsink and separate retention clip, paired with rigid polycarbonate optical light pipes directing PCB SMD LED signals to the front bezel.


6. How to Qualify a Second-Source SFP Cage

While single-port SFP cages often share more standardized envelopes, ganged cages are not universally compatible across different manufacturers. Even minor suffix changes within the same OEM series can alter board compatibility—for example, TE Customer Drawing C-2007215 (Rev C) distinguishes EMI holes on 2007215-1 from a heatsink opening on 2007215-2.

To evaluate an alternate part from LINK-PP’s SFP cage and connector portfolio, start with the incumbent part number (including suffix and drawing revision) and compare both controlled drawings across four checkpoints before PCB release:

  1. PCB Interface: PTH coordinates, pin/tail lengths, finished-hole tolerances, board thickness range, and host connector datum.
  2. Front Panel & Latch Fit: Bezel cutout, cage projection, EMI contact type (spring vs. gasket), insertion depth, and latch clearance.
  3. Cooling & Indicators: Heatsink opening, riding heatsink/clip clearance, light-pipe geometry, and LED pickup coordinates.
  4. Assembly & System Validation: Termination method, seating/extraction tooling, and prototype validation for mechanical fit, thermal margin, high-speed channel integrity (if connector-integrated), and chassis EMC.
Reference OEM P/N OEM Status Reference Architecture Key Drawing Features to Match Qualification Path
TE 2180739-1 Active 1×2 SFP+ Enhanced Ganged Cage Press-fit, EMI spring fingers, heatsink opening, 2.25 mm rec. PCB, 16 Gb/s max rating Request LINK-PP drawing & evaluation samples
TE 2180900-1 Obsolete (Historical Ref.) 1×2 SFP+ Enhanced Ganged Cage Press-fit, elastomeric gasket, heatsink slot, 1.50 mm historical rec. PCB Verify active replacement candidate against PCB & bezel
TE 2007198-1 Active 1×1 SFP+ Single-Port Cage Right-angle, press-fit, EMI springs, 16 Gb/s max rating, no lightpipe Compare single-port PTH pattern & bezel cutout
TE 2007215-1 / -2 Active 1×1 SFP+ Single-Port Cage Press-fit; -1 features EMI holes / -2 features heatsink opening (per C-2007215 Rev C) Match suffix-specific thermal top & tail length
TE 2007262-1 Active 1×2 SFP+ Ganged Cage External EMI springs + 4 optical light-pipe channels (2 LEDs/port) Match 4 LED pickup points & bezel indicator holes
TE 2198708-1 Active 1×1 zSFP+ Cage Rated up to 32 Gb/s, EMI gasket & lightpipe Evaluate against zSFP+ gasket & lightpipe drawing
TE 2170088-1 Active 20-Position zSFP+ Host Receptacle SMT electrical connector (check individual cage rating separately; do not extrapolate 56 Gb/s connector rating to paired cages) Verify connector datum & channel SI with target cage

Frequently Asked Questions

What is the difference between an SFP cage and an SFP connector?

An SFP cage is the external metal housing that guides the transceiver, holds the latch, and provides chassis grounding and EMI shielding. The host connector is the 20-position electrical receptacle that mates with the module’s gold edge contacts. Depending on the part number, they are ordered separately (common in 1×1 and 1×N designs) or supplied as an integrated assembly (common in 2×N stacked and selected ganged products).

What is the difference between a 2×N stacked cage and a belly-to-belly layout?

A 2×N stacked cage places two port rows inside one assembly mounted on a single side of the PCB. A belly-to-belly layout mounts separate cages on opposite surfaces of the same PCB. Stacked designs require checking overall assembly height, connector routing, and cooling for both rows; belly-to-belly designs require checking finished PCB thickness, opposing tail clearance, shared-hole rules, and dual-side assembly access.

Can I reuse a 1G SFP cage for a 10G SFP+ or 25G SFP28 design?

Do not rely on physical insertion alone. Check the exact module and cage drawings for insertion depth, latch engagement, and bezel fit, then verify the host connector and PCB channel for the target rate, confirm module power and case temperature, and validate EMC in the intended chassis.

Can I mirror a single-sided SFP footprint for belly-to-belly mounting?

Use the supplier’s approved double-sided layout for the exact part number where available. Simply mirroring a single-sided footprint can cause opposing press-fit tail interference; always verify finished PCB thickness, tail lengths on both sides, hole designations, and any shared EMI suppression holes.


Request a Cross-Reference & Evaluation Samples from LINK-PP

When evaluating a second-source SFP cage, treat any cross-reference as a candidate for review until dimensional drawings and system validation are complete. Share your target OEM part number (including suffix), port layout, PCB thickness, bezel drawing, and any heatsink or light-pipe requirements to receive corresponding LINK-PP part numbers, drawings, and evaluation samples.