Product Details

Place of Origin: Guangdong,China

Brand Name: LINK-PP

Model Number: 2007464-4

Payment & Shipping Terms

Minimum Order Quantity: 10 pcs

Price: $ 1.90

Packaging Details: Tray or box

Delivery Time: 5–8 working days

Payment Terms: T/T

Supply Ability: 350,000 pcs/month

Get Best Price
Highlight:

2007464-4

,

Press-Fit SFP+ Cage Assembly

,

SFP+ Transceiver Cage with Heatsink

Part Number:
2007464-4
Port Matrix:
1 X 1 (Single Port)
PCB Termination:
Through-hole Press-fit
Data Rate (Max):
Up To 16 Gb/s
Heatsink Height:
13.5 Mm
Assembly H MAX:
22.8 Mm
Insulating Tape:
Included
Lightpipe Included:
No
EMI Containment:
Internal And External Spring Fingers
Catalog Tail Length:
2.05 Mm
Part Number:
2007464-4
Port Matrix:
1 X 1 (Single Port)
PCB Termination:
Through-hole Press-fit
Data Rate (Max):
Up To 16 Gb/s
Heatsink Height:
13.5 Mm
Assembly H MAX:
22.8 Mm
Insulating Tape:
Included
Lightpipe Included:
No
EMI Containment:
Internal And External Spring Fingers
Catalog Tail Length:
2.05 Mm
2007464-4 Press-Fit SFP+ 1x1 Cage Assembly with 13.5 mm Pin Heatsink


2007464-4 is a single-port SFP+ through-hole press-fit cage with a 13.5 mm pin heatsink and underside insulating tape. The drawing specifies a 22.8 mm assembly H MAX before module insertion.


2007464-4 single-port (1×1) SFP+ High-Speed Pluggable I/O Cage Assembly incorporating a pre-installed 13.5 mm [.531 in] Networking Tall Pin-Fin Heat Sink and stainless steel retention clip. Fully compliant with the SFF-8432 specification, it supports serial data rates up to 16 Gb/s (compatible with 10GbE and 16G Fibre Channel).


Designed with an assembled seated height of approximately 23.20 mm [0.913 in], its omnidirectional pin-fin geometry delivers maximum convective cooling for optical transceivers dissipating up to 2.5W in high-airflow rackmount systems. It utilizes compliant Through-Hole Press-Fit pins (2.05 mm tail length) for single-sided PCBs (≥1.50 mm) and belly-to-belly double-sided boards (≥2.25 mm). Constructed from non-magnetic Nickel Silver alloy validated across -55°C to 105°C [-67°F to 221°F].


Gallery images are reference views from the part-specific manufacturer CAD model.


Pin Heatsink and Insulating Tape Specifications of Press-Fit SFP+ Cage Assembly

Parameter Reference specification
Reference part number 2007464-4
Port configuration SFP+ 1 x 1
PCB termination Through-hole press-fit
Heatsink style Pin
Heatsink height 13.5 mm
Assembly H MAX 22.8 mm
Insulating tape Included
Lightpipe None
EMI containment Internal and external spring fingers
Catalog tail length 2.05 mm
Heatsink reference 1829905-2
Cage material 0.25 mm nickel silver alloy
Heatsink finish Electroless nickel-plated aluminum
Clip material Passivated stainless steel
Operating temperature −55 °C to +105 °C
Catalog maximum data rate 16 Gb/s
Catalog recommended PCB thickness 2.25 mm
Drawing minimum PCB thickness (single-sided) 1.50 mm
Drawing minimum PCB thickness (double-sided) 3.00 mm

SFP+ Cage 2007464-4Drawing, Host PCB and Bezel

Use the shared drawing layout on sheet 4 for this suffix. Match the chassis-ground pads and vias and the applicable component and trace keep-outs. Hole A is Ø1.15 ± 0.02 mm drilled with Ø1.05 mm as a finished reference. Hole C is Ø0.95 ± 0.02 mm drilled with Ø0.85 mm as a finished reference. Apply the hole callouts and 114-13120 for plating and installation. Signal pin assignments come from the separately selected host receptacle.

2007464-4 13.5 mm heatsink and cage assembly drawing

2007464-4 PCB layout for cage with insulating tape

2007464-4 bezel cutout and PCB orientation


Mechanical Dimensions, PCB Footprint & Press-Fit Guidelines (2007464-4)


1. Overall Outer Assembly Dimensions:
- Reference Body Depth into PCB: 48.70 mm [1.917 in]
- Front Cage Width: 14.50 mm [0.571 in] (Approx. 15.25 mm across uncompressed external EMI springs)
- Height of Cage Body alone: 9.70 mm [0.382 in]
- Total Seated Height (with 13.5 mm Networking Tall Heat Sink): Approx. 23.20 mm [0.913 in]
- Press-Fit Pin Tail Length: 2.05 mm [0.081 in]


2. Recommended PCB Thickness (Strict Drawing Note):
- Single-Sided Application: 1.50 mm [0.059 in] MINIMUM
- Belly-to-Belly (Double-Sided) Application: 2.25 mm [0.089 in] MINIMUM


3. PCB Press-Fit Hole Layout & Plating Specs (TE Spec 114-13120):
- Drilled Hole Diameter: Ø1.05 ±0.025 mm
- Plated-Through Finished Hole Diameter: Ø0.95 ±0.05 mm
- Copper Plating Thickness: 0.025 mm minimum (25 μm)
- Finished Surface Plating: Immersion Tin (0.5–4.0 μm) or ENIG


4. Recommended Panel Bezel Opening (SFF-8432 Single Port):
- Bezel Opening Width: 15.25 mm ±0.10 mm
- Bezel Opening Height: 10.40 mm ±0.10 mm
- Designed to interface with sheet metal enclosure thicknesses from 0.80 mm to 1.50 mm


5. Press-Fit Tooling & Application Rules (TE Spec 408-10155):
- Tooling Type: Dedicated upper seating tool MUST be used (Do NOT use flat-rock tooling, as it will crush the external EMI spring fingers and damage the tall heat sink clip)
- Seating Force Window: Typical 35 N to 44.5 N [8 to 10 lbf] maximum per compliant press-fit pin (Total insertion force ~385 N to ~490 N for 1x1 cage)



Insulation and Chassis Grounding

The -4 and -3 share a 13.5 mm heatsink and a 22.8 mm H MAX. The -4 adds underside insulating tape. When reviewing a candidate, verify tape coverage, keep-outs and the chassis-ground contacts against the tape-specific layout.

The 16 Gb/s value is a catalog rating. Validate the complete channel and installed module temperature with the actual host receptacle, PCB and module.


Replacement Evaluation and Custom Tooling

LINK-PP can evaluate alternate cage assemblies and custom tooling for the target footprint, bezel, insulation and clearance requirements.

For a quote, share the full suffix, current receptacle part number, PCB footprint and stack-up, bezel drawing, target module and forecast quantity.


FAQ

What does an SFP+ cage do?

The cage guides and retains the module and provides a shielding structure. A separate host receptacle carries the electrical signals.

How should an SFP+ cage connect to chassis ground?

Use the drawing’s chassis-ground pads and vias. Check that the front spring fingers contact the metal bezel in the assembled enclosure.

Can I use a 2.25 mm board for a belly-to-belly layout?

The catalog lists 2.25 mm as recommended. The drawing lists 1.50 mm minimum for mounting on one side and 3.00 mm minimum for double-sided mounting.

Can I use the -3 in place of the -4?

Compare the tape, PCB keep-outs, spring contact and installed clearance, then qualify a sample on the target board.